LINE CLEARANCE CHECKLIST OF AREA & EQUIPMENT FOR PRIMARY PACKING.

LINE CLEARANCE CHECKLIST OF AREA & EQUIPMENT FOR PRIMARY PACKING.

LINE CLEARANCE CHECKLIST OF AREA & EQUIPMENT FOR PRIMARY PACKING.

Compression Cubicle

Ensure the absence of batch documents, labels, materials, powder, tablets, or remnants of previous product or batch.

Ensure ‘CLEANED’ label is affixed on each equipment.

Ensure updating of Status Board for

Temperature [°c], Relative Humidity [%], Differential Pressure [Pascal]

CLEANLINESS of Floor Walls, Ceiling, DrainContainer, Tools, Waste Bins, Light Fixtures.

CLEANLINESS OF Area under compression Machine, Area under the Deduster, Area under the Metal Detector, Area under the balances, Supply air Grills, Return air Grills and Vacuum cleaner.

Blister packing /strip packing and Defoiling machine

CLEANLINESS OF Passbox.

Ensure the absence of batch documents, labels, materials, powder, tablets or remnants of previous product or batch & traces of water on each dismantle part and on each critical part.

CLEANLINESS OF area surrounding the Equipment.

Overprinting Stereos of previous batch or product are destroyed.